banner
Home - Products - Medium voltage power cable - Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated Power Cable
Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®
Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®
Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®
Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®
Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®
Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®
Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®
Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®

Custom Exporters Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated 3-35KV Power Suke Cable®

Medium voltage PVC insulated power cable,the product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.

Brand : Suke Cable®

Voltage : MediumVoltage Cable

Conductor : Copper, Aluminum

Insulation Material : XLPE

Sheath Material : PVC

MOQ : 100 Meters

Whatapp:0086 19942882089

Email: sukecable@fjkangke.com

Product Details

This product is manufactured according to GB/T12706.2, equivalent to IEC60502.2. Or BS, DIN, ICEA standard as customer request.

 

The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.

Suke Wholesale Medium Voltage XLPE PVC Cable

3. Operating characteristics

- Rated power-frepuency voltage U0/U: 3.6/6kv ~ 26/35kv.
- Max.admissible operating temperature of the conductor:90 ºC .
- Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
- The ambient temperature under installation should not below 00C.
- The bending radius of a single-core cable should not less than 20 times of the cable diameter. 
The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 

 

Item Category    A ,B 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV
-
21/35kV
Category    A ,B 6/6kV 8.7/10kV 12/15kV 18/20kV 26/35kV
Single core mm2 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
Three core mm2 25-400 25-400 35-400 50-400 50-400 50-400

OEM ODM Medium Voltage Conductor XLPE Power Cable

4. Table of the voltage, cores and cross-section

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours,Category C includes all the system expect Category A and B.

 

Conductor

 

Insulation thickness (mm)

 

Copper tape screen (approximate) (mm)

 

PVC

bedding thickness (mm)

 

Armored wire outer diameter (mm)

 

Sheath thickness (mm)

 

Outer diameter (approximate) (mm)

 

Copper core cable weight (kg/km)

 

Aluminum core cable weight (kg/km)

Cross sectional area (mm2)

 

Structure

Outer diameter (mm)

25

Compact round

6.0

3.4

0.1

1.3

2.5

2.5

48.0

4175

3703

35

Compact round

7.2

3.4

0.1

1.3

2.5

2.6

50.8

4733

4072

50

Compact round

8.4

3.4

0.1

1.4

2.5

2.7

53.8

5491

4547

70

Compact round

10.0

3.4

0.1

1.5

2.5

2.8

57.6

6446

5124

95

Compact round

11.7

3.4

0.1

1.5

2.5

2.9

61.5

7530

5737

120

Compact round

13.1

3.4

0.1

1.6

2.5

3.0

64.9

8628

6363

150

Compact round

14.6

3.4

0.1

1.6

2.5

3.1

68.3

9794

6963

185

Compact round

16.3

3.4

0.1

1.7

2.5

3.3

72.6

11326

7834

240

Compact round

18.5

3.4

0.1

1.8

3.15

3.5

79.2

14268

9737

300

Compact round

20.7

3.4

0.1

1.9

3.15

3.6

84.8

16641

10978

400

Compact round

23.8

3.4

0.1

2.0

3.15

3.9

92.3

20362

12811

500

Compact round

26.6

3.4

0.1

2.1

3.15

4.1

99.3

24203

14764

 

About us

China Professional Manufacturer Power Wire Cable Factory

 

 

We have alarms on extruding insulation andjacket, to keep 100% quality.

Founded in 1994, Fujian Suke Cable Technology Co., Ltd. Decades of wire and cable manufacturing experience enables us to be one of Top 20 cable manufacturers in China. Our products cover low/medium/extra high voltage power cable, submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, LAN cable, coaxial cable etc, a total of nearly 30 series with 4,000 types and more than 50,000 specifications for various fields within over 100 countries.

 

38

No. of R&D Staff: 38

10

No. of Production Lines:Above 10

7

Number of Foreign Trading Staff:7

130

130 technical staff

3

The company has 3 factories

 

 

Our workshops and certifications

XLPE PVC Cable Wholesaler Workshop

Power Wire And Cable Professional Manufacturer

Custom electrical wire cable manufacturers

Wholesale Industrial Power Cable Suppliers

 

 

Our company has three plants possessing 200 square kilometers and over 4500 employees with 130 technicians creating annual export revenue exceeding 150 Million USD.

 

Also, our company has passed ISO 9001, ISO 14001, ISO45001, OHSAS18001,etc certificatiom, and has got CCC,TLC, TUV, VDE, UL, CE, SAA, BS etc. certificates for our products.

 

 

 

 

FAQ

What is building wire?

Building wire is generally used in house fixed wiring. It is PVC insulated unsheathed electric wire. The onstruction is CU/PVC.

Conductor Structure of Power Cable

1. Conductors comply with IEC, AS/NZS and BSI standard requirements

2. The conductors of multi-core have different shapes. The single-core is circular. The shape of Multi-core cable with size up to and 35m2 can be circular, semicircular and fan-shaped, the conductor with size over and 50m2 are circular and semicircle.

3. A single core is allowed with size below 16m2. Conductor More than 25m2 are multi strands.

Related Products
Leave a Message
Send Email
Whatsapp