Wire Wholesaler FireProof Mineral Insulated 600V 1 KV Cat6 Electriic Suke Cable®
Brand : Suke Cable®
Place of Origin : China
Conductor : Bare Copper Wire
Insulation Material : LSZH
Sheath Material : CCS
MOQ : 100 Meters
Brand : Suke Cable®
Place of Origin : China
Conductor : Bare Copper Wire
Insulation Material : LSZH
Sheath Material : CCS
MOQ : 100 Meters
I Product Details
The cable is a new fireproof cable defects based on modified insulated cables in mineral, it can overcome the disadvantages of mineral insulated cable production is limited by the length of the middle joint installation, avoid appearing in question, has the advantages of the insulation layer is not easy to damp, installation convenience, with the continuous promotion of the product excellent performance, they are increasingly affected by the broad masses of customers, it has been widely used in industrial and civil construction.
II Properties
1. Fireproof performance, fire resistance rating will not only meet the national standard GB12666.6A 950 degree Celsius, 90min, but also to meet the provisions of the United Kingdom BS6387-1994 A Grade of 650 degree Celsius 3H; B 750 degree Celsius 3H; C 950 degree Celsius 3H requirements;
At the same time, in the combustion can tolerance water spray and mechanical impact.
2, continuous length, whether it is single core, or multi-core cable, its length can satisfy the power supply need of length, above each continuous lengths up to 1000m.
3, section of a large, single core cable section is 630mm2, multicore cables up to 70mm2.
4, with flexible, cable disc in the disc, the bending radius is 6-10D;
5, burning smoke-free non-toxic using inorganic materials, insulation, does not produce any harmful gas during burning, no 2 pollution, is the real green environmental protection products;
6, the overload capacity is large, the cable ampacity not only large, but also has large overload capacity. According to the wiring to be shown, usually cable surface temperature ≤ 70 degree Celsius, if the wiring can not touch, nor with the combustible materials in contact, cable sheathing temperature up to 105 degree Celsius. Overload fireproof cable long-term working temperature can reach 250 degree Celsius
7, corrosion resistance, good shielding property, the copper sheath good corrosion resistance, in particular or corrosion of the copper environment, should be applied a layer of low smoke zero halogen or plastic external protecting layer on the copper sheath. In the shielded copper sheath, no electromagnetic interference, have not the signal, control cable transmission information interference
8, good safety, fire cable to normal power supply in the flame (normal power supply 950 degree Celsius for more than 3 hours), starting a fire extinguisher, reducing fire loss. The copper sheath is a good conductor, grounding is best, greatly improve the sensitivity and reliability of grounding protection
9, long service life, high temperature is not easy to aging, in the normal condition, its service life is more than 100 years.
10, flexible fire-proof cable transportation, installation, assembly is simple, similar to that of an ordinary cable,
11, economical, flexible fire-proof cable because of advanced technology, simple installation, low in the same conditions the comprehensive cost than mineral insulated cable charges.
III Scope of Application
Shopping mall, department store, hospital, school, stadium, exhibition center, train station, airport, subway, commercial buildings, hotels, places with dense population, iron and steel enterprises, 100 meters above the building.
Two Core |
||||
Conductor Cross-section |
Copper Sheath Corss-section |
Insulation Thickness |
Approx. Outer Diameter |
Conductor Resistance |
mm2 |
mm2 |
mm |
mm |
Ω/km |
2x2.5 |
10 |
0.8 |
8 |
7.41 |
2x4 |
15 |
0.8 |
9.3 |
4.61 |
2x6 |
17 |
0.8 |
10.7 |
3.08 |
2x10 |
39 |
1 |
14.2 |
1.83 |
2x16 |
45 |
1 |
16.8 |
1.5 |
2x25 |
54 |
1 |
19.3 |
0.727 |
2x35 |
67 |
1.1 |
21.55 |
0.524 |
2x50 |
82 |
1.2 |
19.7 |
0.387 |
2x70 |
96 |
1.2 |
21.9 |
0.268 |
2x95 |
110 |
1.2 |
24.1 |
0.193 |
2x120 |
126 |
1.2 |
25 |
0.153 |
Three Core |
||||
Conductor Cross-section |
Copper Sheath Corss-section |
Insulation Thickness |
Approx. Outer Diameter |
Conductor Resistance |
mm2 |
mm2 |
mm |
mm |
Ω/km |
3x2.5 |
13.6 |
0.8 |
8.8 |
7.41 |
3x4 |
15.4 |
0.8 |
10.2 |
4.61 |
3x6 |
17.4 |
0.8 |
11.3 |
3.08 |
3x10 |
27.7 |
1 |
14.8 |
1.83 |
3x16 |
32.3 |
1 |
17.7 |
1.5 |
3x25 |
44.3 |
1 |
20.4 |
0.727 |
3x35 |
57.8 |
1.1 |
22.7 |
0.524 |
3x50 |
66.2 |
1.2 |
22.8 |
0.387 |
3x70 |
85.8 |
1.2 |
25.6 |
0.268 |
3x95 |
98.1 |
1.2 |
28.5 |
0.193 |
3x120 |
108.7 |
1.2 |
31.3 |
0.153 |
3+1 Core |
||||
Conductor Cross-section |
Copper Sheath Corss-section |
Insulation Thickness |
Approx. Outer Diameter |
Conductor Resistance |
mm2 |
mm2 |
mm |
mm |
Ω/km |
3x16+1x10 |
41.6 |
1 |
18.8 |
1.665 |
3x25+1x16 |
55.9 |
1 |
21.6 |
1.1135 |
3x35+1x16 |
69.6 |
1.1 |
23.7 |
1.012 |
3x50+1x25 |
81.2 |
1.2 |
24.3 |
1.557 |
3x70+1x35 |
93.6 |
1.2 |
28.2 |
0.396 |
3x95+1x50 |
106.4 |
1.2 |
32.8 |
0.29 |
3x120+1x70 |
132.2 |
1.2 |
37.2 |
0.2105 |
Four Core |
||||
Conductor Cross-section |
Copper Sheath Corss-section |
Insulation Thickness |
Approx. Outer Diameter |
Conductor Resistance |
mm2 |
mm2 |
mm |
mm |
Ω/km |
4x6 |
20 |
0.8 |
12.6 |
3.08 |
4x10 |
31.9 |
1 |
16.9 |
1.83 |
4x16 |
43.2 |
1 |
19.2 |
1.5 |
4x25 |
58.1 |
1 |
22.2 |
0.727 |
4x35 |
74.9 |
1.1 |
24.9 |
0.524 |
4x50 |
85.8 |
1.2 |
25 |
0.387 |
4x70 |
99.5 |
1.2 |
28.2 |
0.268 |
4x95 |
113.9 |
1.2 |
32.2 |
0.193 |
4x120 |
139.6 |
1.2 |
35 |
0.153 |
About us
We have alarms on extruding insulation andjacket, to keep 100% quality.
Founded in 1994, Fujian Suke Cable Technology Co., Ltd. Decades of wire and cable manufacturing experience enables us to be one of Top 20 cable manufacturers in China. Our products cover low/medium/extra high voltage power cable, submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, LAN cable, coaxial cable etc, a total of nearly 30 series with 4,000 types and more than 50,000 specifications for various fields within over 100 countries.
38
No. of R&D Staff: 38
10
No. of Production Lines:Above 10
7
Number of Foreign Trading Staff:7
130
130 technical staff
3
The company has 3 factories
Our workshops and certifications
Our company has three plants possessing 200 square kilometers and over 4500 employees with 130 technicians creating annual export revenue exceeding 150 Million USD.
Also, our company has passed ISO 9001, ISO 14001, ISO45001, OHSAS18001,etc certificatiom, and has got CCC,TLC, TUV, VDE, UL, CE, SAA, BS etc. certificates for our products.
FAQ
What is building wire?
Building wire is generally used in house fixed wiring. It is PVC insulated unsheathed electric wire. The onstruction is CU/PVC.
What is the lifespan of a typical electrical cable?
The lifespan can vary widely based on the type of cable and environmental factors, but many cables can last 20 years or more when properly installed and maintained.
What is your sample policy?
As a supplier, we believe that samples are necessary for both of us and our policy is to provide free samples whenever possible. However, if the sample structure is very complicated and we don't have it in stock and it needs to be customised, in this case we have to charge a sample fee. About the sample shipment, you need to pay the shipping fee, you can prepay us the shipping fee we help to send it by express agent, you can also choose express shipping fee to pay.
Conductor Structure of Power Cable
1. Conductors comply with IEC, AS/NZS and BSI standard requirements
2. The conductors of multi-core have different shapes. The single-core is circular. The shape of Multi-core cable with size up to and 35m2 can be circular, semicircular and fan-shaped, the conductor with size over and 50m2 are circular and semicircle.
3. A single core is allowed with size below 16m2. Conductor More than 25m2 are multi strands.