banner
Home - Products - Medium voltage power cable - Medium Voltage Copper Aluminum Conductor XLPE PVC Insulated Power Cable
IEC 60502 BS 6622 Factory Produce 16mm² 3 core SWA Cable Supplier Suke®
IEC 60502 BS 6622 Factory Produce 16mm² 3 core SWA Cable Supplier Suke®
IEC 60502 BS 6622 Factory Produce 16mm² 3 core SWA Cable Supplier Suke®
IEC 60502 BS 6622 Factory Produce 16mm² 3 core SWA Cable Supplier Suke®
IEC 60502 BS 6622 Factory Produce 16mm² 3 core SWA Cable Supplier Suke®

IEC 60502 BS 6622 Factory Produce 16mm² 3 core SWA Cable Supplier Suke®

Our 16mm² SWA cables feature robust construction, ensuring durability and reliability in various industrial and commercial applications. For example: construction, overhead, underground, industrial, power station

Brand : Suke Cable®

Voltage : Medium Voltage Cable

Conductor : Copper

Insulation Material : XLPE

MOQ : 100 Meters

Whatapp:0086 19942882089

Email: sukecable@fjkangke.com

Product Details

Product Description

MV Underground Power Cables Outdoor Energy IEC 60502 BS6622- 6/10 6.35/11kV

6/10kV 12/20kV 18/30kV MV Underground Power Cables Outdoor Energy IEC 60502 BS 6622 6.35/11kV 12.7/22kV 19/33kV SWA Cable

MV Underground Power Cables Outdoor Energy BS 7835 - 6.35/11kV SWA

 

Application

Their aluminium wire armour (AWA) for single core cables and steel wire armour (SWA) for multicore cables provide robust mechanical protection making these MV cables suitable for direct burial in the ground. These armoured MV mains power cables are more commonly supplied with copper conductors but they are also available with aluminium conductors upon request to the same standard. The copper conductors are stranded (Class 2) whereas the aluminium conductors are compliant to the standard using both stranded and solid (Class 1) constructions.

 

Operating Characteristics

1. Laying temperature: 0°C;

2. Cable conductor long-term allowable working temperature: PVC insulated 70°C, XLPE insulated 90°C;

3. Maximum operating temperature in case of short-circuit: PVC insulated 160°C, XLPE insulation 250°C;

4. Cable bending radius:


 

Item

Single-core

Three-core

Non-armored

Armored

Non-armored

Armored

Installation

20D

15D

15D

12D

Close to the terminal and connection box

15D

12D

12D

10D

Note: D is the cable diameter

 

16mm² 3 core SWA Cable

 

MV Cables Construction

 

BS6622

BS7835

Conductor

Class 2 stranded copper or Class 1 solid /Class 2 stranded aluminium

Conductor Screen

Semi-conductive Cross-Linked Polyethylene (XLPE)

Insulation

XLPE

Insulation Screen

Semi-conductive XLPE 

Metallic Screen

Individual or overall copper tape

Filler

Polyethylene Terephthalate (PET) fibres

Separator

Binding Tape

Bedding

Polyvinyl Chloride (PVC)

Low Smoke Zero Halogen (LSZH) compound

Armour

Single core cable: Aluminium Wire Armour (AWA)
Multicore cable: Steel Wire Armour (SWA)

Sheath

PVC or Medium Density Polyethylene (MDPE)

LSZH 

 

Cable models, names, and laying conditions


Model

 

Name

 

Laying Occasion

Copper core

Aluminum core

YJV

YJLV

XLPE insulated PVC sheathed power cable

 

Laid indoors, and in tunnels and pipelines

YJY

YJLY

XLPE insulated PE sheathed power cable

YJV22

YJLV22

XLPE insulated steel tape armored PVC sheathed power cable

 

Adapt for buried laying, not suitable for in-pipe laying

YJV23

YJLV23

XLPE insulated steel tape armored PE sheathed power cable

YJV32

YJLV32

XLPE insulated thin steel wire armored PVC sheathed power cable

 

Laid on riverbeds of rivers or shallow water as connecting lines across rivers or petroleum/natural gas platforms, also  used  in  land high drop areas.

YJV33

YJLV33

XLPE insulated thin steel wire armored PVC sheathed power cable

YJV42

YJLV42

XLPE insulated thick steel wire armored PVC sheathed power cable

YJV43

YJLV43

XLPE insulated thick steel wire armored PE sheathed power cable

 

Armoured 3-core cable with XLPE insualtion. Rated voltage 6/10 KV 6.35/11KV

Data Sheet

Conductor

 

Insulation thickness (mm)

 

Copper tape screen (approximate) (mm)

 

PVC

bedding thickness (mm)

 

Armored wire outer diameter (mm)

 

Sheath thickness (mm)

 

Outer diameter (approximate) (mm)

 

Copper core cable weight (kg/km)

 

Aluminum core cable weight (kg/km)

Cross sectional area (mm2)

 

Structure

Outer diameter (mm)

25

Compact round

6.0

3.4

0.1

1.3

2.5

2.5

48.0

4175

3703

35

Compact round

7.2

3.4

0.1

1.3

2.5

2.6

50.8

4733

4072

50

Compact round

8.4

3.4

0.1

1.4

2.5

2.7

53.8

5491

4547

70

Compact round

10.0

3.4

0.1

1.5

2.5

2.8

57.6

6446

5124

95

Compact round

11.7

3.4

0.1

1.5

2.5

2.9

61.5

7530

5737

120

Compact round

13.1

3.4

0.1

1.6

2.5

3.0

64.9

8628

6363

150

Compact round

14.6

3.4

0.1

1.6

2.5

3.1

68.3

9794

6963

185

Compact round

16.3

3.4

0.1

1.7

2.5

3.3

72.6

11326

7834

240

Compact round

18.5

3.4

0.1

1.8

3.15

3.5

79.2

14268

9737

300

Compact round

20.7

3.4

0.1

1.9

3.15

3.6

84.8

16641

10978

400

Compact round

23.8

3.4

0.1

2.0

3.15

3.9

92.3

20362

12811

500

Compact round

26.6

3.4

0.1

2.1

3.15

4.1

99.3

24203

14764

Note: The single-core armored cables are used for the D.C. system only. If used for the A.C. system, the magnetic isolation should be applied to the steel armor wires of non-magnetical materials that should be used.

 

 Operating characteristics

- Rated power-frepuency voltage U0/U: 6.35/11kV.

- Max.admissible operating temperature of the conductor:90ºC.

- Max. short-circurt temperature of conductor shall not exceed 250ºC. (5s maximum duration)

- The ambient temperature under installation should not below 0ºC.

- The bending radius of a single-core cable should not less than 20 times of the cable diameter.

The bending radius of a multi-core cable should not less than 15 times of the cable diameter.

 

16mm² 3 core SWA Cable

 

 

About us

China Professional Manufacturer Power Wire Cable Factory

 

 

We have alarms on extruding insulation andjacket, to keep 100% quality.

Founded in 1994, Fujian Suke Cable Technology Co., Ltd. Decades of wire and cable manufacturing experience enables us to be one of Top 20 cable manufacturers in China. Our products cover low/medium/extra high voltage power cable, submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, LAN cable, coaxial cable etc, a total of nearly 30 series with 4,000 types and more than 50,000 specifications for various fields within over 100 countries.

 

38

No. of R&D Staff: 38

10

No. of Production Lines:Above 10

7

Number of Foreign Trading Staff:7

130

130 technical staff

3

The company has 3 factories

 

 

Our workshops and certifications

XLPE PVC Cable Wholesaler Workshop

Power Wire And Cable Professional Manufacturer

Custom electrical wire cable manufacturers

Wholesale Industrial Power Cable Suppliers

 

 

Our company has three plants possessing 200 square kilometers and over 4500 employees with 130 technicians creating annual export revenue exceeding 150 Million USD.

 

Also, our company has passed ISO 9001, ISO 14001, ISO45001, OHSAS18001,etc certificatiom, and has got CCC,TLC, TUV, VDE, UL, CE, SAA, BS etc. certificates for our products.

 

 

 

 

FAQ

What is building wire?

Building wire is generally used in house fixed wiring. It is PVC insulated unsheathed electric wire. The onstruction is CU/PVC.

How do I know if a cable is compliant with standards?

Look for certification marks or labels on the cable, such as those from IEC, UL, or other relevant regulatory bodies that indicate compliance with safety and performance standards.

What are armoured cables?

Armoured cables have an additional layer of protection (usually metal) to prevent physical damage. They are often used in harsh environments or where cables may be exposed to impact.

Conductor Structure of Power Cable

1. Conductors comply with IEC, AS/NZS and BSI standard requirements

2. The conductors of multi-core have different shapes. The single-core is circular. The shape of Multi-core cable with size up to and 35m2 can be circular, semicircular and fan-shaped, the conductor with size over and 50m2 are circular and semicircle.

3. A single core is allowed with size below 16m2. Conductor More than 25m2 are multi strands.

Related Products
Leave a Message
Send Email
Whatsapp